Test Environment

1.Normal temperature
2.Voltage : 3.6V~4.2V

Test Instruments

CMU200 Universal Radio Communication Tester
DC Power Supply

Test Cases

Test Case#1

GSM 900 Power level 5
Test Channel 1~124
Test Item:Average burst power

The MS’s average power is between 30 dBm to 36 dBm