Test Environment
1.Normal temperature
2.Voltage : 3.6V~4.2V
Test Instruments
CMU200 Universal Radio Communication Tester
DC Power Supply
Test Cases
Test Case#1
GSM 900 Power level 5
Test Channel 1~124
Test Item:Average burst power
The MS’s average power is between 30 dBm to 36 dBm